Sie sind hier: Startseite» MARCH US Pump Assemblies» Series 2» AC-2CP-MD Mag Drive Pump

AC-2CP-MD Mag Drive Pump

AC-2CP-MD Mag Drive Pump
Für eine größere Ansicht klicken Sie auf das Vorschaubild

 

March Pump’s industrial AC-2CP-MD is an American seal-less centrifugal magnetic drive pump ideal for applications such as chemical recirculation and chemical transfer. It is capable of generating a maximum flow of 5 gallons per minute at 2 feet, and its maximum head is 13 Feet (5.5PSI).

Unit60Hz
SystemUSMetric
Max Flow5 GPM 18.9 LPM
Max Head13 FT4 M
Power0.025 HP0.019 KW
Unit50Hz
SystemUSMetric
Max Flow4.9 GPM18.5 LPM
Max Head8.9 FT2.7 M
Power0.025 HP0.019 KW
Electrical/Air: 115V 50/60Hz or 230V 50/60Hz
Inlet: 3/8"FPT & 3/4"MPT
Outlet: 1/4"MPT
  • Wet End: Polypropylene (Front and Rear Housing, Impeller), Viton (O-Ring), Ceramic (Shaft, Thrust Washer), Ceramic Magnet
  • Max Internal Pressure: 50 PSI / 3.4 bar
  • Max Liquid Temperature: 190 °F / 87 °C
  • Note: Product image may be different than actual product received.

Part Numbers

P/NPump DescriptionModified With
0125-0069-0100AC-2CP-MD 115VStandard
0125-0069-0300AC-2CP-MD 230VStandard
The below are modified AC-2CP-MD's
0125-0069-0164AC-2CP-MD 115VEncapsulated Impeller
0125-0069-0364AC-2CP-MD 230VEncapsulated Impeller
0125-0069-0162AC-2CP-MD 115VEncapsulated Impeller and EPDM O-Ring
0125-0069-0362AC-2CP-MD 230VEncapsulated Impeller and EPDM O-Ring

Parts Breakdown

Parts Image
ItemPart NumberQtyDescription
0125-0069-01001AC-2CP-MD, 1 Phase, 115V, Complete Standard Pump
0125-0069-03001AC-2CP-MD, 1 Phase, 230V, Complete Standard Pump
10115-0062-10006#7-19 x 1-7/16" Long Self-Tapping Screw (Stainless)
20125-0056-10001Cover with 3/8” FPT x 3/4” MPT Inlet (Polypropylene)
30125-0065-100013/32" CS x 2-3/16" OD "O" Ring (Viton)
40130-0028-10001Thrust Washer (Ceramic)
50125-0061-10001Shaft (Ceramic)
60125-0055-01001Impeller with Bare Ceramic Magnet (Polypropylene)
70125-0058-10001Rear Housing with 1/4” MPT Outlet (Polypropylene)
80125-0083-010010.250” Bore Drive Magnet
90150-0015-10004#8-32 x 1/2” Long Screw (Stainless)
100858-0004-10004#8 Washer (Stainless)
110125-0069-10001Motor Bracket (Plastic)
120125-0052-10001Motor, 1 Phase, 115V, 50/60 Hz,
120125-0063-10001Motor, 1 Phase, 230V, 50/60 Hz,
WEK0125-0108-02001Wet End Kit (Items: 1, 2, 3, 4, 5, 6, 7)

 

Options

Options Image
ItemPart NumberQtyDescription
20125-0079-10001Cover with 3/8” FPT x 3/4” MPT Inlet (Delrin)
30125-0066-100013/32” CS x 2-3/16” OD “O” Ring (Buna N)
30125-0135-100013/32"CS x 2-3/8" OD (Teflon)
30750-0180-100013/32” CS x 2-3/16” OD “O” Ring (EPDM)
50125-0125-10001Shaft (Stainless)
60125-0081-01001Impeller with Bare Ceramic Magnet (Delrin)
60125-0087-02001Encapsulated Impeller (Polypropylene)
70125-0080-10001Rear Housing with 1/4” MPT Outlet (Delrin)
0750-1011-10001Stainless Steel Tag w/Customer's Desired Information (Not Shown)

Motor Information

0125-0052-1000 Motor
3 Foot Cord
60Hz: 1Ph 115V 0.025HP/0.019kW, 1.2 AMPS, 3450 RPM
50Hz: 1Ph 115V 0.025HP/0.019kW, 1.2 AMPS, 2850 RPM

0125-0063-1000 Motor
3 Foot Cord
60Hz: 1Ph 230V 0.025HP/0.019kW, 0.6 AMPS, 3450 RPM
50Hz: 1Ph 230V 0.025HP/0.019kW, 0.6 AMPS, 2850 RPM

Please contact us for alternative motor data

Perfect for Applications Including

Applications for the AC-2CP-MD Mag Drive include etching equipment, photographic processing equipment, ice makers, ice flakers, plate processors, and marine air conditioning.

Great for Chemicals Including

The AC-2CP-MD has pumped has pumped Acetic Acid, Acetone, Ammonium Sulfate, Citric Acid, Ethylene Glycol, Ferric Sulfate, Hydrogen Peroxide, Potassium Hydroxide, Sodium Chloride, Fresh Water, Salt Water, and many more chemicals. The AC-2CP-MD may have been modified to handle these chemicals. This pump may have to be modified to pump specific gravities, viscosities, or elevated temperatures different then ambient water. Please contact March Pump to review your application before using the AC-2CP-MD. Chemical Resistance Chart

Summary Paragraph

March Pump’s industrial AC-2CP-MD is an American seal-less centrifugal magnetic drive pump ideal for applications such as chemical recirculation and chemical transfer. It is capable of generating a maximum flow of 5 gallons per minute at 2 feet, and its maximum head is 13 Feet (5.5PSI). The standard wet end (the materials that come into contact with the solution) is composed of Polypropylene, Viton, Ceramic, and Ceramic Magnet. The inlet connection is 3/8 female pipe thread and 3/4 male pipe thread, and the outlet is 1/4 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.025 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options). The maximum internal pressure the pump can tolerate is 50PSI, and the maximum liquid temperature is 190 Fahrenheit or 87 Celsius. The March AC-2CP-MD centrifugal magnetic drive pump is capable of handling mildly or highly corrosive chemicals, acids, and solvents. To determine if the March AC-2CP-MD is suitable for your application, please contact March Pump.


 


MARCH Pumpen GmbH & Co. KG
Rathenaustrasse 2, 35394 Gießen

 +49 (0) 641 / 68 68 06 – 0
 +49 (0) 641 / 68 68 06 – 60
 info(at)march-pumpen.com